Menu
Mon - Fri 8:00am - 8:00pm EST
See Trending Products

You have no items in your shopping cart.

GREE VIR09HP115V1AH

9,000 BTU 23 SEER Ductless Mini Split Wall Mount Indoor Unit 115V

SKU : VIR09HP115V1AH
blank image

About this Item

GREE Vireo Series, 3/4 Ton, Wall Mount, Single-Zone, Mini-Split Heat Pump Indoor Unit - 9,000 BTU, R-410a, 115 VAC
  • Energy Star Estimated Cooling Cost: $103
  • SEER: 23
This item has been retired by the manufacturer and is no longer available. You may find similar products by viewing our selection of Single Zone Components below.
Looking for Help or Advice?
Our dedicated team is here to help you through the process of selecting the right system or part.

Product Highlights

The Gree Vireo VIR09HP115V1AH is a slim wall mounted indoor air handler, designed to be paired with the VIR09HP115V1AO 9,000 BTU Vireo outdoor condenser.

The unit is designed to blend well in any living space. The slim compact cabinet hangs inconspicuous on the wall and mixes well with most interior designs. The Vireo wall mounted units have an easy-to-read display and indicator lights, which provide information on room set point, operating mode among other features. The display may be turned off for your convenience.

The Vireo comes with a multi-functional infrared hand held remote control that is sleek, easy to use and ergonomically designed with a large LCD display.

Features & Benefits:

  • Multiple speed fan
  • Timer
  • I Feel mode
  • IR remote control
  • Adjustable airflow
  • Privacy lock mode
  • Sleep mode
  • Fahrenheit °F / Celsius °C
  • Quiet operation
  • Polymeric air filters
  • 5/7 year limited warranty

Manuals & Docs

Gree VIR09HP115V1AH - 9,000 BTU 23 SEER Ductless Mini Split Wall Mount Indoor Unit 115V
Weight 23 Pound (lb.)
Height 11.4 Inches (In)
Width 33.3 Inches (In)
UPC 813919020478
Length 8.2 Inches (In)
Brand GREE
Equipment Type Heat Pump
SEER 23.00
EER (Energy Efficiency Ratio) 13.0
Refrigerant R-410a
CFM 377
Rated Cooling Capacity (BTU) 9,000
Rated Heating Capacity (BTU) 9,900
Nominal Capacity (BTU) 9,000
Voltage 115 VAC
Phase Single
Cycle/Hertz 60
Suction Line Size 3/8"
Liquid Line Size 1/4"
Color White
Mounting Type Wall Mount
Sound Level (dBA) 26-43
Warranty Offered 7 Year Compressor - 5 Year Parts to Original Registered End-User with Proof of Proper Installation
Energy Star Rated Yes
Dehumidity Pints/Hr 1.7
Filter Type Washable Polymeric Air Filter
4-Way Remote Air Flow Control No
Model Family Vireo
Tonnage 3/4

Remote Controller

Remote Control

Part Name

  • ON/OFF Button
  • Fan Button
  • Mode Button
  • Up Button
  • Swing Button
  • Turbo Button
  • Down Button
  • Temp Button
  • Sleep Button
  • I Feel Button
  • Clock Button
  • Light Button
  • Timer On/Off Button

INTRODUCTION FOR ICONS ON DISPLAY SCREEN

Remote display icon

REMOTE CONTROLLER OPERATIONS

The wireless remote controller is sleek, versatile and allows you to change room temperatures and functions on your Vireo system from the palm of your hand. The large LCD display and buttons make it easy-to-understand and easy-to-use.

The remote controller is set from factory to display temperatures in °F. If °C is desired, turn the remote controller OFF with the ON/OFF button and then press “MODE“ and buttons on the remote simultaneously for 5 seconds.

On mode display

ON/OFF BUTTON

When the system is in OFF mode, the remote controller will display the time and last room setpoint. When you press the ON/OFF button, this indicator will be displayed and the unit will start in the last operating mode and room setpoint.

NOTE: If the ON/OFF button is pressed too soon after a stop, the compressor will not start for 1 to 5 min. due to the inherent protection against frequent compressor cycling.

On mode display

DISPLAYING SETPOINT, INDOOR OR OUTDOOR
TEMPERATURE ON FRONT PANEL:

The setpoint temperature, outdoor temperature or room temperature can be displayed on the front panel. Only setpoint temperature is displayed on the remote controller.

When the “TEMP” button is pushed once, the temperature indicator Indicator icon is displayed. This indicates that the setpoint temperature is displayed on the front panel.

When the “TEMP” button is pushed a second time, the display will show an Indicator icon icon with a thermometer inside a house. This indicates that the room temperature is displayed on the front panel.

When the "TEMP” button is pushed a third time, the display will show an Indicator icon icon with a thermometer outside a house. This indicates that the outdoor temperature is displayed on the front panel. (Not available on some models).

The room temperature and outdoor temperature will be displayed for only 5 seconds before reverting back to displaying room setpoint.

Icon

VERTICAL SWING LOUVERS

  • Press the Vertical Swing Louver button to select five different vertical (up & down) air discharge directions including Continuous Sweep. The Swing Louver Icon icon will be displayed. Press this button to set swing angle, which changes in direction as below: Icon image Icon Indicates louver swings back and forth in the five directions, as shown.

Icon

PRIVACY LOCK

The Privacy Lock prevents unauthorized access to the unit controls and prevents tampering with system settings. The remote controller can be locked by pushing the "" and "" buttons simultaneously for 5 seconds. The Privacy Lock icon will be displayed on the remote controller. Repeat the process to unlock the remote controller.

Icon

I FEEL MODE

Press this button to use the I FEEL function, and the (Icon) icon will be displayed. The unit will sense room temperature at the remote controller instead of at the indoor unit. It then adjusts airflow and temperature accordingly for the ultimate in personal comfort control and energy savings. Press the button again to exit this function. For best performance, keep remote controller away from heat or cold temperature sources while using this function.

On mode display

MODE BUTTON

Use the “MODE” button to select one of the available modes. The selected mode will be displayed on the remote controller and the appropriate light will illuminate on the front display panel.

  • AUTO – Unit will automatically select heating or cooling to maintain room temperature between 68°F and 77°F. The remote controller will display the Auto Mode icon with no setpoint.

    COOL – To cool to selected setpoint and remove moisture. Press or to adjust set temperature. System varies compressor speed to maintain desired temperature.

    HEAT – To heat to selected room setpoint. Press or to adjust set temperature. System varies compressor speed to maintain desired room temperature.

    FAN ONLY – To circulate air without heating or cooling. Use Fan Speed button to select speed from low to high.

    DRY – Select DRY MODE to increase moisture removal during warm humid conditions. In this mode, fan speed cannot be adjusted.

    • If the Room Temperature is more than 4°F above the set temperature, the system will be operating in cooling mode with low fan speed.

    • If the Room Temperature is between 4°F higher than, and 4°F less than, the set temperature, the system will cycle 6 minutes ON and 4 minutes OFF in cooling mode. The indoor fan will be at low speed.

    • If the Room Temperature is more than 4°F below the set temperature, the system will be OFF and the indoor fan will be at low speed.

Icon

FREEZE GUARD

In Heat mode, press"TEMP"and "CLOCK" buttons simultaneously to start up 46°F heating function. When this function is started up, "($)" and "46°F" will be displayed on the remote controller, and the unit will maintain room temperature above 46°F. Press"TEMP" and "CLOCK" buttons simultaneously again to cancel Freeze Guard protection.

Icon

TIMER SETTING

Timer-ON / Timer-OFF BUTTON

To set when you want the unit to turn On at the end of a selected time period, use the button labeled “Timer-ON/Timer-OFF”on the remote controller. Press this button to make the clock icon disappear, replaced with the word “ON” (blinking). Press or buttons to adjust timer setting 1 minute at a time. Press and hold or button to set timer more quickly. Press“Timer-ON/Timer-OFF” button again to confirm setting, and the word “ON” will stop blinking. To cancel, press“Timer-ON/Timer-OFF” button again.

To set when you want the unit to turn Off at the end of a selected time period, use the same button. Press this button to make the clock icon disappear, replaced with the word “OFF” (blinking). Adjust settings the same as with“Timer-ON/Timer-OFF”settings.

NOTE: Under Timer On and Off status, you can set“Timer-ON/Timer-OFF”simultaneously. Before setting timer, be sure to set clock to correct time.

Icon

TURBO MODE

The desired room setpoint can be achieved faster in TURBO mode. After selecting the “HEAT” or “COOL” mode button, push the “TURBO” button. The TURBO Icon icon will be displayed on the remote controller and the unit will run at an ultra-high speed. To deactivate the feature, push the “TURBO” button again. The unit will return to normal operation.

Icon

LIGHT BUTTON

Press this button to turn off display light on indoor unit. Press again to turn it back on.

Icon

FAN BUTTON

Press the FAN button to adjust the indoor fan speed:
Low ( Icon ) Medium ( Icon ), High ( Icon ), Turbo and Auto.

  • Turbo function is not available in Dry and Auto mode.

  • The fan operates at low speed in Dry and Auto modes, and the speed cannot be adjusted.

  • When Auto is selected, the unit will select the proper fan speed automatically, according to the ambient temperature

NOTE: Turbo function is not available in Dry and Auto Modes. The Vireo unit will select proper fan speed automatically according to ambient temperature

Icon

CLOCK SETTING

Press this button to set clock time.“” icon on remote controller will blink. Within 5 seconds, press or button to set clock time. With each pressing of or buttons, clock time will increase or decrease 1 minute. To quickly adjust time setting, press and hold or button for 2 seconds. Release button when you have reached the desired time setting. Press “CLOCK” button to confirm the time, and “” icon will stop blinking.

NOTE: Clock time adopts 24-hour mode. A 12-hour time format is not available.

Icon

ENERGY-SAVING

In Cool mode, press"TEMP" and "CLOCK" buttons simultaneously to start the energy-saving function."SE" will be shown on remote controller, and the unit will adjust the set temperature automatically to reach to the best energy-saving effect. Press"TEMP"and "CLOCK" buttons simultaneously again to cancel energy-saving mode.

Icon

SLEEP MODE

The Vireo system will automatically adjust room temperature during your sleep time. This slight change in temperature will not affect your comfort level due to the natural effects that sleeping has on the body, but it will save on energy consumption and will lower your electric bill. The Vireo System has three Sleep Modes to select from. Press the SLEEP button to select Sleep 1, Sleep 2, Sleep 3 modes or Cancel. The SLEEP Icon icon will appear.

TRADITIONAL MODE - SLEEP 1 Icon

In Traditional Mode the unit will slowly relax the room set temperature by up to 4° F until Sleep Mode is cancelled.

Image
Image

TRADITIONAL MODE - SLEEP 2 Icon

In Expert Mode the unit will adjust the room set temperature at a rate based on the starting set temperature value. Sleep Mode will continue until cancelled.

Image
Image

DIY MODE - SLEEP 3 Icon

You will be required to enter eight (8) room setpoint values for eight (8) hours of run time. The last room setpoint value will be maintained until sleep mode is cancelled.

In Sleep Mode 3, press "Prog" button to enter setup mode. The remote controller will display “1:00” in the time location. Use the “+” and “-“ buttons to select the desired room setpoint for the first hour of run time. Then press the “Prog” button to save the setpoint.

The remote controller time display will change to “2:00.” Once again, use the “+” and “-“ buttons to select the desired room setpoint for the second hour of run time, and press the “Prog” button to again save the setpoint.

Repeat this sequence for the eight (8) room setpoint values. After all eight (8) values have been entered, the remote controller will automatically revert to standard time and temperature display, and the Sleep 3 Mode will begin.

At any time, you may press the “ON/OFF," " Mode," " Timer," "Sleep” or “Turbo" buttons to cancel the Sleep 3 Mode.

NOTE: During this procedure, if no button is pressed within 10 seconds, remote controller will automatically exit the sleep curve setting and resume original display. If ON/OFF, MODE, TIMER, SLEEP, COOLING or HEATING button is pressed during the setting or inquiry procedure, remote controller will also exit the sleep curve setting.

Sleep function will be disabled if the air conditioner is restarted after power failure; Sleep function can not be set in AUTO mode.

CHANGING BATTERIES AND ADDITIONAL NOTES

To change batteries, slide cover off battery compartment on back of remote controller. Remove and safely discard old batteries. Insert two new AAA 1.5V dry batteries, using correct polarity. Reattach back cover.

NOTE:

  • If the remote controller will not be used for a long time, remove batteries to prevent leakage damage.
  • Be sure to aim the remote controller at the receiver of the main unit when operating.
  • When remote emits a signal, icon will flicker; a tone will be heard when unit receives that signal.

CHANGING BATTERIES

Remove batteries
Remove batteries

DAMAGED OR LOST REMOTE CONTROLLER

If remote controller is lost or damaged, the Vireo system can be turned off directly from the indoor unit. Lift the front panel of the indoor wall unit, then press the AUX button to turn on or turn off. When the unit is on, it will operate in AUTO Mode.

Warning
There are no reviews for this item. Write Review
Start typing your question and we'll check if it was already asked and answered. Learn More
Browse 2 questions Browse 2 questions and 1 answer
No questions have been asked about this item. Be the first!